Are there any requirements for the placement and height of filing cabinets?
Date of release:2020-06-30 Author: Click:
Are there any requirements for the placement and height of Jiangxi filing cabinets?
Provincial Archives Office:
According to the "Code for Design of Archives Buildings" (JGJ25-2010), the net height of archives should not be less than 2.60m. The arrangement of archive fixtures (such as archive cabinets) in the archive should be arranged in rows perpendicular to the wall with windows. The channel between archive fixtures should correspond to the external wall lighting window, and if there is no window, it should correspond to the direction of the ventilation hole opening in the pipeline.
The dimensions of each part of the arrangement of archival equipment should comply with the following regulations:
1. The net width of the main channel should not be less than 1.20m;
2. The net width between two rows of archive fixtures should not be less than 0.80m;
3. The net distance between the end of the archive fixture and the wall should not be less than 0.60m;
The net distance between the back of the archive fixture and the wall should not be less than 0.10m.
In addition, the standard value of uniformly distributed live load on the floor of the archive should not be less than 5kN/m2, and when using dense racks, it should not be less than 12kN/